TPX® DX310

About
TPX™   DX310 TPX™ DX310 is a Polymethylpentene Copolymer (PMP Copolymer) material. It is available in North America for extrusion coating, fiber (spinning) extrusion, or injection molding. Primary attribute of TPX™ DX310: Good Stiffness.&&TPX™   DX310 TPX™ is a 4-methylpentene-1-based olefin copolymer. TPX™ has a unique molecular structure. Although TPX™ is a crystalline olefin polymer, it shows transparency. Because of its excellent heat-resistance, release property and chemical resistance, TPX™ is used for industrial materials, including mandrels and sheaths in the manufacture of high-pressure rubber hose, mold cups to create LED light and other applications such as release film on FPC manufacturing process and release paper in the manufacture of synthetic leather. Furthermore, TPX™ possesses a lowest density among thermoplastic polymers and then provides the molded articles with lower weight. This leads to reduce the environmental load for transportation. It is also noted that TPX™ is a halogen-free polymer denoted as environmentally-friendly material. TPX™ is also used for food-related applications such as food wraps, food preservation packs, baking carton and microwave oven tableware.&&

Product Description
SupplierMitsui
GenericPoly 4-methylpentene-1 copolymer
Material StatusCommercial: Active
FeaturesGood Rigidity
AvailabilitysNorth America

Technical Data
PHYSICALNominal valueUnitTest method
Density0.834g/cm³Internal Method
Melt Flow Rate
260℃,5.0kg100g/10minInternal Method
Water absorption rate
saturated< 0.010%ASTM D570

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
Injection molding19J/mASTM D256
Notched impact strength of cantilever beam
23 ℃, injection molding29J/mASTM D4812

THERMALNominal valueUnitTest method
Hot deformation temperature
0.45 MPa, unannealed, 6.35 mm80.0ASTM D648
Vicat Softening Temp145ASTM D1525 5
Crystallization peak temperature
DSC226ASTM D3418
Linear coefficient of thermal expansion
MD:-10~160℃1.2E-41/℃Internal Method

Electrical performanceNominal valueUnitTest method
Volume resistivity
2 mm> 1.0E+16ohms·cmASTM D257
Dielectric strength
2 mm32kV/mmASTM D149
Dielectric constant
2.00 mm,1 MHz2.15 ASTM D150

optical performanceNominal valueUnitTest method
Refractive index1.463 ASTM D542
Transmittance
injection molding93.0%ASTM D1003
Haze
Injection molded film1.7%ASTM D1003

MECHANICALNominal valueUnitTest method
Rockwell hardness
R-level< 50 ASTM D785
Tensile modulus
23 ℃, injection molding850MPaASTM D638
tensile strength ASTM D638
Yield, 23 ℃, injection molding20.0MPaASTM D638
Fracture, 23 ℃, injection molding10.0MPaASTM D638
Tensile strain
Fracture, 23 ℃, injection molding52%ASTM D638
Bending modulus
3.20 mm, injection molded, 51 mm span490MPaASTM D790
bending strength
3.20 mm, injection molded, 51 mm span18.0MPaASTM D790

Process Conditions
injectionNominal valueUnitTest method
ExtrusionNominal valueUnitTest method
Barrel rear temperature270°C
Barrel middle temperature280°C
Barrel front temperature300°C
Mold temperature20 to 60°C
Injection pressure30.0 to 40.0MPa
Hold pressure30.0MPa
Barrel 1 zone temperature280°C
Barrel 2 zone temperature290°C
Barrel 3 zone temperature290°C
Barrel 4 zone temperature290°C
Connector temperature290°C
Nozzle temperature290°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. Type IV, 2.0 in/min
3. Chuck Distance: 65mm
4. 0.051 in/min
5. 120°C/hr
6. Heat Speed: 120°C/hour
7. Rate A (50°C/h), Loading 1 (10 N)
8. TMA Method, Applied Force: 3g, Nitrogen Flow: 100mL/min
9. Injection Molded
10. Wave Length: 589nm
11. Injection Molded, 2 mm, 589 nm wavelength
12. C Illuminant
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.