ULTEM™ 2410EPR resin

About
40% Glass fiber filled, high flow Polyetherimide (Tg 217C) with internal mold release for enhanced electroplatability. ECO Conforming, UL94 V0 listing.&&

Product Description
SupplierSABIC
GenericPolyetherimide
Material StatusCommercial: Active
FeaturesHigh liquidity,Electroplating,ECO,V-0
AvailabilitysNorth America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.56g/cm³ASTM D792
Density1.56g/cm³ISO 1183
Melt Flow Rate
337℃,6.60kg8.9g/10minASTM D1238
Melt Volume Rate
360℃,5 kg11.0cm³/10minISO 1133
Shrinkage rate Internal Method
MD0.20 to 0.40%Internal Method
MD:3.2 mm0.20 to 0.40%Internal Method
Shrinkage rate
TD:3.2 mm0.30 to 0.50%Internal Method
Water absorption rate
Saturation, 23 ℃0.80%ISO 62
Equilibrium, 23 ℃, 50% RH0.40%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃10kJ/m²ISO 179/1eA
23℃10kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃35kJ/m²ISO 179/1eU
23℃30kJ/m²ISO 179/1eU
Impact strength of cantilever beam notch ISO 180/1A
23℃410J/mASTM D4812
23℃82J/mASTM D256
-30℃10kJ/m²ISO 180-1A
23℃10kJ/m²ISO 180-1A
Notched impact strength of cantilever beam ISO 180/1U
-30℃30kJ/m²ISO 180/1U
23℃30kJ/m²ISO 180/1U
Dart impact equipped with measuring instruments
23℃,Total Energy18.0JASTM D3763

THERMALNominal valueUnitTest method
Hot deformation temperature 
0.45 MPa, unannealed, 100 mm span208ISO 75-2/Be
0.45 MPa, unannealed, 64 mm span206ISO 75-2/Bf
Hot deformation temperature ASTM D648
1.8 MPa, unannealed, 3.2 mm204ASTM D648
1.8 MPa, unannealed, 6.4 mm208ASTM D648
Vicat Softening Temp223ASTM D1525 12
Vicat Softening Temp 
B50214ISO 306
B120215ISO 306/B120
Ball pressure test
125℃Pass IEC 60695-10-2
Linear coefficient of thermal expansion
TD:23~150℃4.5E-51/℃ISO 11359-2
TD:-40~150℃4.5E-51/℃ASTM E831
MD:23~150℃1.5E-51/℃ISO 11359-2
MD:-40~150℃1.5E-51/℃ASTM E831
Thermal conductivity coefficient0.30W/m/KISO 8302

Electrical performanceNominal valueUnitTest method
Arc resistancePLC 5 ASTM D495
Compared to the leakage tracing indexPLC 4 UL 746
High Arc Burning Index (HAI)PLC 4 UL 746
High voltage arc marking rate
HVTRPLC 4 UL 746
Hot wire ignition
HWIPLC 4 UL 746

FLAME CHARACTERISTICSNominal valueUnitTest method
0.40 mmV-0 UL 94

MECHANICALNominal valueUnitTest method
Tensile modulus11100MPaASTM D638
Tensile modulus11000MPaISO 527-1-2
tensile strength
fracture165MPaASTM D638
fracture170MPaISO 527-2/5
yield170MPaISO 527-2/5
yield165MPaASTM D638
Tensile strain
fracture1.8%ASTM D638
fracture2.0%ISO 527-2/5
yield2.0%ISO 527-2/5
yield1.8%ASTM D638
Bending modulus9500MPaISO 178
50 mm span10700MPaASTM D790
bending strength220MPaISO 178
bending strength
Yield, 50 mm span240MPaASTM D790
Ball hardness
H358/30165MPaISO 2039-1

Special valueNominal valueUnitTest method
0.45 MPa, unannealed, 3.2 mm212ASTM D648
0.45 MPa, unannealed, 6.4 mm215ASTM D648
1.8 MPa, unannealed, 100 mm span205ISO 75-2/Ae
1.8 MPa, unannealed, 64 mm span197ISO 75-2/Af

Process Conditions
injectionNominal valueUnitTest method
Drying temperature149°C
Drying time4.0 to 6.0hr
Drying time, maximum24hr
Recommended maximum moisture content0.020%
Recommended injection volume40 to 60%
Barrel rear temperature332 to 399°C
Barrel middle temperature338 to 399°C
Barrel front temperature343 to 399°C
Nozzle temperature343 to 399°C
Processing (melt) temperature349 to 399°C
Mold temperature135 to 163°C
Back pressure0.345 to 0.689MPa
Screw speed40 to 70rpm
Vent depth0.025 to 0.076mm

Notes
1. Typical properties: these are not to be construed as specifications.
2. Tensile Bar
3. 0.20 in/min
4. Type I, 0.20 in/min
5. 0.051 in/min
6. 0.079 in/min
7. at Yield
8. 80*10*4 sp=62mm
9. 80*10*4 mm
10. 120*10*4 mm
11. Rate A (50°C/h), Loading 2 (50 N)
12. Tungsten Electrode
13. Surface
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.