Ultradur® B 4300 G2 High Speed

About
Easy flowing injection molding grade with 10% glass fibers; for rigid, tough and dimensionally stable technical parts (eg timer dials, toggles, knobs, parts for thermostats, oven-door handles, toaster housings and grills).&&

Product Description
SupplierBASF
Genericpolybutylene terephthalate
Material StatusCommercial: Active
FeaturesGood Rigidity,Good flexibility,Good Dimensional Stability,Good liquidity
AvailabilitysEurope
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.37g/cm³ISO 1183
Shrinkage rate
MD0.95%ISO 294-4
TD1.10%ISO 294-4
Water absorption rate
23℃,24hr0.20%ISO 62
23℃,50% RH0.40%ISO 62
Melt Flow Rate
250℃,2.16kg37g/10minISO 1133

MECHANICALNominal valueUnitTest method
tensile strength
23℃85.0MPaISO 527-2
Tensile strain
Fracture, 23 ℃3.5%ISO 527-2
Bending modulus
23℃4400MPaISO 178

THERMALNominal valueUnitTest method
melting point220-225
Hot deformation temperature
0.45 MPa, unannealed210ISO 75-2/Bf
1.8 MPa, annealed162ISO 75-2/Af

Electrical performanceNominal valueUnitTest method
Volumetric resistance1.0E+14Ω.cmIEC 60093
Insulation strength
20KV/mmIEC 60243-1
Dissipation factor
Compared to the leakage tracing index300VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
0.75mmUL 94
1.50mmHBUL-94
3.00mmHBUL-94

IMPACTNominal valueUnitTest method
Charpy Unnotch Impact strength
23℃20.0kJ/m²ISO 179/1eU
Charpy Notched Impact Strength
23℃3.5kJ/m²ISO 179/1eA

Process Conditions
injectionNominal valueUnitTest method
Injection temperature
Mold temperature60-100°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. solution 0,005 g/ml Phenole/1,2 Dichlorbenzol 1:1
3. plate with film gate 150*150*3 mm³
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.