Ultraform® W2320 003 AT

About

Product Description
SupplierBASF
GenericPOM
Material StatusCommercial: Active
FeaturesFast Cure,Good liquidity

Technical Data
PHYSICALNominal valueUnitTest method
Density1.41g/cm³ISO 1183
Molding shrinkage
Parallel2%ISO 294-4
Vertical normal2.1%ISO 294-4
Moisture Absorption
50% r.h.0.2%ISO 62
Saturation0.8%ISO 62
Melt Volume Rate
190℃,2.16kg25ccm/10minISO 1133

MECHANICALNominal valueUnitTest method
Tensile Modulus2850MPaISO 527
Tensile Stress
Yield yld65MPaISO 527
Tensile Strain
Yield yld8%ISO 527
Broken BRK24%ISO 527

IMPACTNominal valueUnitTest method
Izod Notched Impact strength
-30℃5KJ/m²ISO 180/1A
23℃5KJ/m²ISO 180/1A
Charpy Notched Impact Strength
-30℃4kJ/m²ISO 179
23℃4.5kJ/m²ISO 179
Charpy Unnotch Impact strength
-30℃190kJ/m²ISO 179
23℃190kJ/m²ISO 179

THERMALNominal valueUnitTest method
Melting point166ISO 3146
Hot deformation temperature HDT100ISO 75-1/-2
Coeff. of linear thermal expansion1.1×10-4/℃

ELECTRICALNominal valueUnitTest method
Compared Tracking Index600IEC 60112
Volume Resistance1E11ohm·mIEC 60093
Surface Resistivity1E13ohmIEC 60093
Dielectric Constant3.81 MHZIEC 60250
Dissipation Factor501 MHzIEC 60250

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame Class Rating
0.75 mmHBUL 94
1.5 mmHBUL 94
3.0 mmHBUL 94
Glow Wire Flammability Index (GWFI)
Electrical
0.75 mm105UL746B
1.5 mm105UL746B
3.0 mm105UL746B
Mechanical w/Impact
1.5 mm90UL746B
3.0 mm90UL746B
Non mechanical w/o Impact
1.5 mm90UL746B
3.0 mm105UL746B

Process Conditions
Injection MoldingNominal valueUnitTest method
Drying Temperature80-110
Drying Time2-4hr
Maximum Moisture Content0.15%

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.