Ultramid® A3XG3 BK20562

About
Ultramid A3XG3 BK20562 is a 15% glass fiber reinforced injection molding PA66 grade with improved flame retardance and enhanced long-term heat stability. The grade is based on red phosphorous and exhibits exceptional mechanical properties and outstanding surface finish. Flame performance has been determined to be V0 at 0.8mm per the UL94 method.&&

Product Description
SupplierBASF
GenericPA66
Material StatusCommercial: Active
FeaturesGood surface appearance,Flame Characteristics,Grease resistance,V-0
AvailabilitysNorth America
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.34g/cm³ISO 1183
Shrinkage rate ISO 294-4
TD1.1%ISO 294-4
MD0.50%ISO 294-4

MECHANICALNominal valueUnitTest method
Tensile modulus
23℃6740MPaISO 527-2
tensile strength
Fracture, 23 ℃120MPaISO 527-2
Tensile strain
Fracture, 23 ℃2.8%ISO 527-2
Bending modulus
23℃6150MPaISO 178
bending strength
23℃183MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179
-30℃4.2kJ/m²ISO 179
23℃4.8kJ/m²ISO 179
Charpy Unnotch Impact strength ISO 179
-30℃35kJ/m²ISO 179
23℃45kJ/m²ISO 179
Impact strength of cantilever beam notch ISO 180
-40℃4.5kJ/m²ISO 180
23℃4.8kJ/m²ISO 180

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed222ISO 75-2/A
0.45 MPa, unannealed250ISO 75-2/B
Melting temperature
DSC260ISO 3146

FLAME CHARACTERISTICSNominal valueUnitTest method
0.80 mmV-0 UL 94

Process Conditions
injectionNominal valueUnitTest method
Drying temperature80°C
Drying time2.0 to 4.0hr
Recommended maximum moisture content0.050%
Processing (melt) temperature285 to 300°C
Mold temperature80 to 90°C
Injection pressure3.45 to 10.3MPa
Injection speedFast 

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.