UNIGARD™ RE DFDA-1638 NT

About
UNIGARD™ RE DFDA-1638 Natural is a non-halogen, flame retardant, thermoplastic, low smoke, low corrosive, and low toxic compound. It has been designed for general purpose, medium and low voltage applications. If needed, standard color concentrates (EVA or PE based) can be used. Used as jacket, it is designed to pass the IEC-332-3, the IEEE-383/UL-1685 vertical tray cable burn tests. Cable construction, of course, plays an important role in flame performance. DFDA-1638 Natural can be used as jacket for 90°C rated cables. DFDA-1638 Natural is also designed to maximize processing and flame performance. This compound can sustain extrusion temperatures up to 362°F (200°C) and can be extruded in typical single-flight metering PE screws, barrier screws, Maddock screws, and screws with mixing pins. Features UNIGARD RE DFDA-1638 Natural provides the following features: Highly flame retardant (VW-1, IEC-332-3, IEEE 383 flame test ratings) Environmentally friendly (lead-free, halogen-free, sulfur/antimony-free) Low smoke, low corrosivity, and low toxicity UV stabilized Contains copper inhibitor Ease of extrusion and no special screw required Good electrical properties, moisture resistance, and fluid resistance Good balance of toughness and flexibility Excellent cut-through, crush, and abrasion resistance Colorable for insulation and jacket applications&&

Product Description
SupplierDOW
Generic热塑性聚酯
Material StatusCommercial: Active
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.50g/cm³ASTM D1505
Mechanical water absorption rate
70℃,7days9.50mg/in²UL 1581
ESCR(Environmental Stress Cracking Resistance)
10% non-ionic detergent720hrASTM D1693

elastic bodyNominal valueUnitTest method
tear strength6.13kN/mASTM D470

Aging performanceNominal valueUnitTest method
Tensile strength retention rate
10 days,110℃110%ASTM D638
Elongation retention rate
10 days,110℃89%ASTM D638

THERMALNominal valueUnitTest method
Embrittlement temperature-25.0ASTM D746
thermal deformation UL 1581
90℃2.8%UL 1581
100℃10%UL 1581
121℃48%UL 1581
Oxygen sensing time
Al pans,no crimping,no screen,100 ml oxygen/min25minASTM D3895

Electrical performanceNominal valueUnitTest method
Volume resistivity
23℃3.5E+14ohms·cmASTM D257
Dielectric constant ASTM D150
60 Hz3.42 ASTM D150
100 kHz3.49 ASTM D150
1 MHz3.42 ASTM D150
6 MHz3.34 ASTM D150
Dissipation factor ASTM D150
60 Hz3.7E-3 ASTM D150
100 kHz7.6E-3 ASTM D150
1 MHz0.014 ASTM D150
6 MHz0.016 ASTM D150

FLAME CHARACTERISTICSNominal valueUnitTest method
Extreme oxygen index39%ASTM D2863
Acid gas test
Generation0.47%MIL C-24643
toxicity1.40 NES 713
Acid gas emission pH4.50 IEC 754-2
Conductivity of acidic gas emissionsNo conductivity increase of the test fluid IEC 754-2
Temperature index (combustion) – Critical> 350NES 715
smoke
2.54 mm5.30 NES 711
Smoke density ASTM E662
Flaming Mode – D1.5:2.54 mm0.62 ASTM E662
Flaming Mode – D4.0:2.54 mm1.0 ASTM E662
Flaming Mode – Dm,(corr.):2.54 mm82 ASTM E662
Non combustion mode – D1.5:2.54 mm0.24 ASTM E662
Non combustion mode – D4.0: 2.54 mm16 ASTM E662
Non combustion mode – Dm, (cor.): 2.54 mm290 ASTM E662

MECHANICALNominal valueUnitTest method
Shore hardness
Shaw’s A89 ASTM D2240
tensile strength12.4MPaASTM D638
Tensile strain
fracture180%ASTM D638
Bending modulus
1% secant214MPaASTM D790
Wear resistance
1000 cycle2%ASTM D1044
Shrinkback(4 hrs,100℃)1.0%REA 89

Notes
1. Typical properties: these are not to be construed as specifications.
2. No Cracks
3. #14 AWG (1.63 mm dia.) solid copper conductor with 0.030 in (0.76 mm) insulation.
4. #14 AWG (1.63 mm dia.) solid copper conductor with 0.045 in (1.1 mm) insulation.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.