VAMPAMID HT 3028 V0

About
PPA resin, 30% glass fiber reinforced, flame retardant halogen free for injection molding&&

Product Description
GenericPPA
Material StatusCommercial: Active
FeaturesHalogen free,Flame Characteristics,V-0
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.44g/cm³ASTM D792
Shrinkage rate ASTM D955
MD0.30%ASTM D955
TD0.70%ASTM D955
Water absorption rate
24hr0.40%ASTM D570

MECHANICALNominal valueUnitTest method
Tensile modulus12000MPaISO 527-2
tensile strength
fracture160MPaISO 527-2
Tensile strain
fracture1.9%ISO 527-2

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch6.0kJ/m²ISO 180/A
Notched impact strength of cantilever beam45kJ/m²ISO 180

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed270ASTM D648-A
Ball pressure test
200℃通过 IEC 60695-10-2

Electrical performanceNominal valueUnitTest method
Surface resistivity> 1.0E+12ohmsASTM D257
Dielectric strength36kV/mmIEC 60243-1
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
0.40 mmV-0 UL 94
0.80 mmV-0 UL 94
1.60 mmV-0 UL 94
3.20 mmV-0 UL 94
Glowing wire flammability index
1.0-2.0 mm960IEC 60695-2-12
Igniting temperature of the hot wire
1-2 mm775IEC 60695-2-13

Supplementary informationNominal valueUnitTest method
temperature
long-term150

Process Conditions
injectionNominal valueUnitTest method
Drying temperature90°C
Drying time3.0hr
Processing (melt) temperature320°C
Mold temperature130°C

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.