VAMPLEN 3026 V0 CB T DF

About
UL 94 V0 at 0,8 mm, 30% glass fiber reinforced, chemically bonded, thermostabilized, RoHS.&&

Product Description
GenericPP not specified
Material StatusCommercial: Active
FeaturesFlame Characteristics,Hypocrystalline,Chemical coupling,Heat Stabilized
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.49g/cm³ASTM D792
Shrinkage rate
MD0.30%
TD0.70%
Water absorption rate
saturated0.020%ASTM D570

MECHANICALNominal valueUnitTest method
Tensile modulus8000MPaASTM D638
tensile strength
yield55.0MPaASTM D638
Tensile strain
fracture2.0%ASTM D638

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch7.0kJ/m²ISO 180/A
Notched impact strength of cantilever beam20kJ/m²ISO 180

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed140ASTM D648-A
Vicat Softening Temp120ASTM D1525 3
Relative temperature index120UL 746
Electrical performance120UL 746
Impact mechanical performance120UL 746

Electrical performanceNominal valueUnitTest method
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
0.80 mmV-0 
1.60 mmV-0 
3.20 mmV-0 
Glowing wire flammability index
1.0-2.0 mm850IEC 60695-2-12

Process Conditions
injectionNominal valueUnitTest method
Drying temperature70°C
Drying time3.0hr
Processing (melt) temperature210°C
Mold temperature60°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. Loading 2 (50 N)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.