| VESTAMID® Care ME grades represent a range of flexible polyether block amide (PEBA) resins of varying hardness for processing via extrusion or injection molding. VESTAMID® Care ME materials are available as standard and bonding-modified grades. VESTAMID® Care ME standard grades have a proven history in catheter applications. Due to their broad range of flexibility, VESTAMID® CareME grades are used in different parts of catheter constructions – may it be the distal end, requiring a low modulus for non-traumatic insertion, or the proximal end, needing a high modulus for force and torque transmission. The advantages at a glance: High flexibility & elasticity Good rebound properties High impact resistance High dimensional stability High chemical resistance High toughness Easy processability & colorability Free of volatile plasticizers&& |
| Product Description | |
|---|---|
| Supplier | Evonik |
| Generic | PA12弹性体 |
| Material Status | Commercial: Active |
| Features | Excellent Processability,Good flexibility,High impact resistance,Good Dimensional Stability,High elastic,Biocompatible,Solvent resistance,Good coloring,HB |
| Availabilitys | North America,Europe |
| Process Methods | Extrusion |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.03 | g/cm³ | ISO 1183 |
| Shrinkage rate | ISO 294-4 | ||
| TD:3.0 mm | 0.90 to 1.4 | % | ISO 294-4 |
| MD:3.0 mm | 0.60 to 1.1 | % | ISO 294-4 |
| Water absorption rate | |||
| Saturation, 23 ℃ | 1.1 | % | ISO 62 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Shore hardness | |||
| Shaw’s D | 62 | ISO 868 | |
| Tensile modulus | 370 | MPa | ISO 527-2 |
| tensile strength | |||
| Yield, 23 ℃ | 42.0 | MPa | ISO 527-2/50 |
| 50% strain, 23 ℃ | 23.0 | MPa | ISO 527-2/50 |
| Tensile strain | |||
| Fracture, 23 ℃ | > 200 | % | ISO 527-2/50 |
| Tensile creep modulus | |||
| 1000 hr | 200 | MPa | ISO 899-1 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179/1eA | ||
| -30 ℃, completely fractured | 8.0 | kJ/m² | ISO 179/1eA |
| 23 ℃, localized fracture | 120 | kJ/m² | ISO 179/1eA |
| Charpy Unnotch Impact strength | ISO 179/1eU | ||
| -30℃ | No Break | ISO 179/1eU | |
| 23℃ | No Break | ISO 179/1eU |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | |||
| 1.8 MPa, unannealed | 45.0 | ℃ | ISO 75-2/A |
| 0.45 MPa, unannealed | 100 | ℃ | ISO 75-2/B |
| Vicat Softening Temp | |||
| — | 165 | ℃ | ISO 306/A |
| — | 110 | ℃ | ISO 306/B |
| Linear coefficient of thermal expansion | |||
| TD:23~55℃ | 2.0E-4 | 1/℃ | ISO 11359-2 |
| MD:23~55℃ | 2.0E-4 | 1/℃ | ISO 11359-2 |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| 1.60 mm | HB | UL 94 |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |