VESTAMID® L L-GF15

About
Reinforced, filled and flame-retardant VESTAMID® polyamide 12 compounds Characterization: 15% chopped strands, medium viscosity, heat stabilized with processing aid Applications: gear box housing for electrical car window lifters In general, it can be said that long-chain, semi-crystalline polyamides absorb little water, are resistant to polar and non-polar solvents, exhibit low creep behavior and high impact resistance and can be used in a wide temperature range. Virtually no other polymer material in this price range exhibits these properties.&&

Product Description
SupplierEvonik
GenericPA12
Material StatusCommercial: Active
FeaturesExcellent Processability,High impact resistance,Low or no water absorption,noise reduction,Flame Characteristics,Food contact compliance,Fatigue resistance,Good wear resistance,Grease resistance,Solvent resistance,Heat Stabilized,High ESCR,Fuel resistance,HB,V-2
AvailabilitysNorth America,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.12g/cm³ISO 1183
Shrinkage rate ISO 294-4
TD0.65%ISO 294-4
MD0.35%ISO 294-4
Water absorption rate
Saturation, 23 ℃1.3%ISO 62
Equilibrium, 23 ℃, 50% RH0.60%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus3900MPaISO 527-2
tensile strength
fracture95.0MPaISO 527-2
Tensile strain
fracture6.0%ISO 527-2

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30 ℃, completely fractured11kJ/m²ISO 179/1eA
23 ℃, completely fractured17kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30 ℃, completely fractured80kJ/m²ISO 179/1eU
23 ℃, completely fractured75kJ/m²ISO 179/1eU

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed160ISO 75-2/A
0.45 MPa, unannealed175ISO 75-2/B
Vicat Softening Temp 
175ISO 306/A
170ISO 306/B
Melting temperature178ISO 11357-3
Linear coefficient of thermal expansion
MD:23~55℃8.0E-51/℃ISO 11359-2

Electrical performanceNominal valueUnitTest method
Volume resistivity1.0E+15ohms·cmIEC 60093
Dielectric strength44kV/mmIEC 60243-1
Relative permittivity IEC 60250
23℃,100 Hz4.00 IEC 60250
23℃,1 MHz3.40 IEC 60250
Dissipation factor IEC 60250
23℃,100 Hz0.038 IEC 60250
23℃,1 MHz0.026 IEC 60250
Compared to the leakage tracing index IEC 60112
CTI600VIEC 60112
Solution A> 600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.60 mmHB UL 94
3.20 mmV-2 UL 94

Supplementary informationNominal valueUnitTest method
Electrolytic corrosionA1 IEC 60426
ISO ShortnamePA12, MHR, 16-050, GF15 ISO 1874

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2nd heating
3. 100 Drop Voltage
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.