Visico™ FR4451/LE4439

About
Visico FR4451/LE4439 – is a natural UV stabilized, halogen free moisture-induced crosslinkable polyethylene compound that is designed for use in photovoltaic cables. The combination of a VISICO base resin, and the catalyst, provides a highly scorch retardant compound with excellent thermal stability and good flame retardant properties. Visico FR4451/LE4439 contains a patented scorch retardant additive (SRA) that increases the processing window for a moisture crosslinking compound and minimizes the tendency for premature crosslinking in the extruder, head or die. Visico FR4451/LE4439 can be readily pigmented to a variety of colors using standard wire & cable color concentrates designed for thermoplastic or crosslinked polyethylene. When properly mixed, 5 parts of LE4439 to 95 parts of FR4451, insulation with excellent thermo-oxidative stability, also in contact with copper and aluminium, is achieved. Application Visico FR4451/LE4439 is designed for use as flexible single-core cables (cords) for use at the DC-side of photovoltaic systems with maximum permissible voltage of DC 1.8 kV. Specifications Cables manufactured with FR4451/ LE4439 using sound extrusion practice comply with the following cable product standard TÜV 2 PfG 1169/08.2007, EN 50618 and EN 50363-5 EI5 type.

Product Description
SupplierBorealis AG
GenericXLPE
Material StatusCommercial: Active
FeaturesWeather resistance is good,Halogen free,Flame Characteristics,Heat Stabilized,Good coloring
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.19g/cm³ISO 1183
Melt Flow Rate
190℃,2.16kg0.50g/10minISO 1133

THERMALNominal valueUnitTest method
thermosetting
Elongation under load: 200 ℃< 50%
Permanent deformation: 200 ℃< 5.0%

Electrical performanceNominal valueUnitTest method
Volume resistivity9.0E+15ohms·cmIEC 60093
Dielectric strength> 20kV/mmIEC 60243-1
Relative permittivity
50 Hz3.13 IEC 60250
Dissipation factor
50 Hz0.013 IEC 60250

FLAME CHARACTERISTICSNominal valueUnitTest method
Extreme oxygen index32%ISO 4589-2
Corrosive gases in flue gas< 100µS/cmEN 50267-2-2
Single Vertical Flame TestPass IEC 60332-1

Supplementary informationNominal valueUnitTest method
Hot pressing test
240 hr,140℃Pass IEC 60811-508

MECHANICALNominal valueUnitTest method
Shore hardness
Shore D, 15 seconds40 ISO 868
tensile strength16.0MPaIEC 60811-501
Tensile strain
fracture400%IEC 60811-501
Bending modulus100MPaISO 178

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.