About |
---|
Vydyne R530 NAT is general-purpose, injection-molding grade, 30% glass-fiber reinforced PA66 resin. Available in natural, it is lubricated for good machine feed, flow and mold release.&& |
Product Description | |
---|---|
Supplier | Ascend |
Generic | PA66 |
Material Status | Commercial: Active |
Features | Good liquidity,Antifreeze,Solvent resistance,HB,Heat Stabilized,Fatigue resistance,Hydrolysis stability,Gasoline resistance,Lubricating |
Availabilitys | North America,Europe,Asia Pacific |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.37 | g/cm³ | ISO 1183 |
Molding shrinkage | ISO 294-4 | ||
TD:23℃,2.0 mm | 0.90 | % | ISO 294-4 |
MD:23℃,2.0 mm | 0.40 | % | ISO 294-4 |
Water Absorption | |||
Balanced Equilibrium, 23 ℃, 50% RH | 1.9 | % | ISO 62 |
23℃,24hr | 0.90 | % | ISO 62 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile Modulus | |||
23℃ | 10000 | MPa | ISO 527-2 |
Tensile Strength | |||
Broken BRK, 23 ℃ | 195 | MPa | ISO 527-2 |
Tensile Strain | |||
Broken BRK, 23 ℃ | 3.0 | % | ISO 527-2 |
Flexural Modulus | |||
23℃ | 9600 | MPa | ISO 178 |
Flexural Strength | |||
23℃ | 270 | MPa | ISO 178 |
Poisson’s ratio | |||
23℃ | 0.40 | ISO 527 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179 | ||
-30℃ | 10 | kJ/m² | ISO 179 |
23℃ | 11 | kJ/m² | ISO 179 |
Charpy Unnotch Impact strength | ISO 179 | ||
-30℃ | 65 | kJ/m² | ISO 179 |
23℃ | 75 | kJ/m² | ISO 179 |
Izod Notched Impact strength | ISO 180 | ||
-30℃ | 10 | kJ/m² | ISO 180 |
23℃ | 12 | kJ/m² | ISO 180 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature HDT | |||
1.8 MPa, unannealed | 250 | ℃ | ISO 75-2/A |
0.45 MPa, unannealed | 260 | ℃ | ISO 75-2/B |
Melting temperature | 260 | ℃ | ISO 11357-3 |
Coeff. of linear thermal expansion | |||
TD:23~55℃,2 mm | 1.1E-4 | 1/℃ | ISO 11359-2 |
MD:23~55℃,2 mm | 2.2E-5 | 1/℃ | ISO 11359-2 |
Relative Temperature Index (RTI) | |||
Electrical performance | UL 746 | ||
0.75 mm | 120 | ℃ | UL 746 |
1.5 mm | 120 | ℃ | UL 746 |
3.0 mm | 120 | ℃ | UL 746 |
Strength mechanical performance | UL 746 | ||
0.75 mm | 115 | ℃ | UL 746 |
1.5 mm | 120 | ℃ | UL 746 |
3.0 mm | 120 | ℃ | UL 746 |
Impact mechanical performance | UL 746 | ||
0.75 mm | 85.0 | ℃ | UL 746 |
1.5 mm | 85.0 | ℃ | UL 746 |
3.0 mm | 105 | ℃ | UL 746 |
ELECTRICAL | Nominal value | Unit | Test method |
---|---|---|---|
Volume Resistance | |||
3.0 mm | 1.0E+14 | ohms·cm | IEC 60093 |
Dielectric Strength | |||
1 mm | 24 | kV/mm | IEC 60243 |
Arc Resistance | |||
3.0 mm | PLC 5 | ASTM D495 | |
Compared Tracking Index | |||
3.00 mm | 600 | V | IEC 60112 |
High Arc Burning Index (HAI) | UL 746 | ||
0.75 mm | PLC 0 | UL 746 | |
1.5 mm | PLC 0 | UL 746 | |
3.0 mm | PLC 0 | UL 746 | |
High Voltage Arc Track Rate | |||
HVTR | PLC 1 | UL 746 | |
Hot wire ignition | |||
HWI | UL 746 | ||
0.75 mm | PLC 4 | UL 746 | |
1.5 mm | PLC 4 | UL 746 | |
3.0 mm | PLC 4 | UL 746 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame Class Rating | UL 94 | ||
0.75 mm | HB | UL 94 | |
1.50 mm | HB | UL 94 | |
3.00 mm | HB | UL 94 |
Process Conditions | |||
---|---|---|---|
Injection Molding | Nominal value | Unit | Test method |
Drying Temperature | 80 | °C | |
Drying Time | 4.0 | hr | |
Suggested maximum proportion of recycled materials | 25 | % | |
Rear Temperature Zone 1 | 280 to 310 | °C | |
Middle Temperature Zone 2 | 280 to 310 | °C | |
Front Temperature Zone 3 | 280 to 310 | °C | |
Nozzle temperature | 280 to 310 | °C | |
Melt Temperature | 285 to 305 | °C | |
Mold Temperature | 65 to 95 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |