XANTAR® LDS 3735

About
Laser Direst Structuring (LDS), Impact Modified&&

Product Description
SupplierMitsubishi
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesHigh impact resistance,HB
AvailabilitysNorth America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.24g/cm³ISO 1183
Melt Flow Rate
260℃,5.0kg13g/10minISO 1133
Shrinkage rate
MD0.60%ISO 294-4
Water absorption rate
Equilibrium, 23 ℃, 50% RH0.35%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus2200MPaISO 527-2
tensile strength
yield50.0MPaISO 527-2
Tensile strain
yield5.0%ISO 527-2
Nominal tensile fracture strain> 50%ISO 527-2
Bending modulus2100MPaISO 178
bending strength80.0MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃35kJ/m²ISO 179/1eA
23℃45kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃No Break ISO 179/1eU
23℃No Break ISO 179/1eU
Impact strength of cantilever beam notch ISO 180/4A
-20℃40kJ/m²ISO 180-4A
23℃50kJ/m²ISO 180-4A
Multi axial instrumented impact energy
23℃40.0JISO 6603-2

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed121ISO 75-2/A
Vicat Softening Temp
B50141ISO 306
Linear coefficient of thermal expansion
TD6.0E-51/℃ISO 11359-2
MD6.0E-51/℃ISO 11359-2

Electrical performanceNominal valueUnitTest method
Surface resistivity> 1.0E+15ohmsIEC 60093
Volume resistivity> 1.0E+15ohms·cmIEC 60093
Relative permittivity
1.00 GHz2.88 IEC 60250
Dissipation factor
1 GHz6.0E-3 IEC 60250

FLAME CHARACTERISTICSNominal valueUnitTest method
Flammability level
0.75 mmHB IEC 60695-11-10, -20

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.