XENOY™ X4850 resin

About
XENOY X4850 is a hydrostable, high modulus, high ductile PC/PBT blend. Furthermore, this resin provides high chemicalresistance, very low creep, low CTE, excellent fatique and high heat dimensional stability. The X4850 could be positioned for body panels, safety equipment,housings, doorhandles, spring-loaded applications, medical device enclosures, outdoor sports equipment.&&

Product Description
SupplierSABIC
GenericPC+PBT
Material StatusCommercial: Active
FeaturesGood flexibility,Good Dimensional Stability,Ductility,Hydrolysis stability,Fatigue resistance,Solvent resistance
AvailabilitysNorth America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.31g/cm³ASTM D792
Density1.31g/cm³ISO 1183
Melt Flow Rate
266℃,5.0kg4.5g/10minASTM D1238
Melt Volume Rate
265℃,5 kg4.00cm³/10minISO 1133
Shrinkage rate
MD:3.2 mm0.70 to 0.90%Internal Method
Water absorption rate
Saturation, 23 ℃0.42%ISO 62
Equilibrium, 23 ℃, 50% RH0.14%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃11kJ/m²ISO 179/1eA
23℃20kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃No Break ISO 179/1eU
23℃No Break ISO 179/1eU
Impact strength of cantilever beam notch ASTM D256
-30℃100J/mASTM D256
0℃120J/mASTM D256
23℃180J/mASTM D256
Impact strength of cantilever beam notch ISO 180/1A
-30℃7.0kJ/m²ISO 180-1A
0℃11kJ/m²ISO 180-1A
23℃20kJ/m²ISO 180-1A
Notched impact strength of cantilever beam ISO 180/1U
-30℃No Break ISO 180/1U
23℃No Break ISO 180/1U
Dart impact equipped with measuring instruments ASTM D3763
-20℃,Total Energy60.0JASTM D3763
23℃,Total Energy60.0JASTM D3763
Multi axial instrumented impact energy100JISO 6603-2

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed, 64 mm span99.0ISO 75-2/Af
1.8 MPa, unannealed, 3.2 mm101ASTM D648
0.45 MPa, unannealed, 64 mm span121ISO 75-2/Bf
0.45 MPa, unannealed, 3.2 mm125ASTM D648
Vicat Softening Temp134ASTM D1525 11
Vicat Softening Temp 
B50133ISO 306
B120135ISO 306
Linear coefficient of thermal expansion
TD:-40~40℃7.5E-51/℃ASTM E831
TD:-30~80℃8.1E-51/℃ISO 11359-2
MD:-40~40℃5.2E-51/℃ASTM E831
MD:-30~80℃6.3E-51/℃ISO 11359-2
Thermal conductivity coefficient0.20W/m/KISO 8302

MECHANICALNominal valueUnitTest method
Tensile modulus4000MPaASTM D638
Tensile modulus
3850MPaISO 527-1-2
tensile strength 
yield58.0MPaASTM D638
yield65.0MPaASTM D638
yield58.0MPaISO 527-2/5
yield63.0MPaISO 527-2/50
tensile strength 
fracture60.0MPaASTM D638
fracture55.0MPaASTM D638
fracture50.0MPaISO 527-2/5
fracture45.0MPaISO 527-2/50
Tensile strain 
yield3.4%ISO 527-2/5
yield3.5%ISO 527-2/50
yield3.8%ASTM D638
yield3.7%ASTM D638
Tensile strain ASTM D638
fracture140%ASTM D638
fracture130%ASTM D638
fracture80%ISO 527-2/5
fracture30%ISO 527-2/50
Bending modulus3500MPaISO 178
50 mm span3700MPaASTM D790
bending strength94.0MPaISO 178
bending strength
Yield, 50 mm span99.0MPaASTM D790
Taber abraser
1000 cycles, 1000 g, CS-17 wheels30.0mgInternal Method
Ball hardness
H358/30105MPaISO 2039-1

Process Conditions
injectionNominal valueUnitTest method
Drying temperature90 to 100°C
Drying time2.0 to 4.0hr
Recommended maximum moisture content0.020%
Hopper temperature40 to 60°C
Barrel rear temperature230 to 250°C
Barrel middle temperature240 to 265°C
Barrel front temperature250 to 270°C
Nozzle temperature250 to 265°C
Processing (melt) temperature255 to 270°C
Mold temperature60 to 80°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. 0.20 in/min
3. Type I, 2.0 in/min
4. Type I, 0.20 in/min
5. 0.051 in/min
6. 0.079 in/min
7. Yield
8. 80*10*4 sp=62mm
9. 80*10*4
10. 80*10*4 mm
11. Rate B (120°C/h), Loading 2 (50 N)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.